1,798 research outputs found

    Long-term planning of low voltage networks

    Get PDF

    Long-term planning of low voltage networks

    Get PDF

    AC Loss and Contact Resistance In Copper-Stabilized Nb3Al Rutherford Cables with and without a Stainless Steel Core

    Get PDF
    Calorimetric measurements of AC loss and hence interstrand contact resistance (ICR), were measured on three samples of Rutherford cable wound with Cu-stabilized jelly-roll type unplated Nb3Al strand. One of the cable types was furnished with a thin core of AISI 316L stainless steel and the other two were both uncored but insulated in different ways. The cables were subjected to a room-temperature-applied uniaxial pressure of 12 MPa that was maintained during the reaction heat treatment (RHT), then vacuum impregnated with CTD 101 epoxy, and repressurized to 100 MPa during AC-loss measurement. The measurements were performed at 4.2 K in a sinusoidal field of amplitude 400 mT at frequencies of 1 to 90 mHz (no DC-bias field) that was applied both perpendicular and parallel to the face of the cable (the face-on, FO, and edge-on, EO, directions, respectively). For the cored cable the FO-measured effective ICR (FO-ICR), was 5.27 . Those for the uncored cables were less than 0.08 . As shown previously for NbTi- and Nb3Sn-based Rutherford cables, the FO-ICR can be significantly increased by the insertion of a core, although in this case it is still below the range recommended for accelerator-magnet use. Post-measurement dissection of one of the cables showed that the impregnating resin had permeated between the strands and coated the core with a thin, insulating layer excepting for some sintered points of contact. In the uncored cables the strands were coated with resin except for the points of interstrand contact. It is suggested that in the latter case this tendency for partial coating leads to a processing-sensitive FO-ICR.Comment: Four pages, with two figure

    Valuation of measurement data for low voltage network expansion planning

    Get PDF
    The introduction of electric vehicles and photovoltaics is changing the residential electricity consumption. Distribution network operators (DNO) are investing in an advanced metering infrastructure (AMI) to enable cost reduction through smart grid applications. The DNO also benefits from the additional measurement data the AMI gives for the network planning process. The availability of AMI data can be limited by the cost of communication and by privacy concerns. To determine the social welfare of an AMI, the economic gains should be estimated. For the planning of the low voltage (LV) network, a method for determining the value of an AMI still needs to be developed. Therefore, a planning methodology which allows various levels of measurement data availability has been developed. By applying this approach the value of different levels of AMI from an LV-network planning perspective can be determined. To illustrated the application of this approach a case study for the LV-network of a Dutch DNO is performed. The results show that an increase in measurement data can lead to €49-254 lower LV-network reinforcement costs. A detailed analysis of the results shows that already 50% of the possible cost reduction can be achieved if only 65% of the households have AMI data available.</p

    Valuation of measurement data for low voltage network expansion planning

    Get PDF
    The introduction of electric vehicles and photovoltaics is changing the residential electricity consumption. Distribution network operators (DNO) are investing in an advanced metering infrastructure (AMI) to enable cost reduction through smart grid applications. The DNO also benefits from the additional measurement data the AMI gives for the network planning process. The availability of AMI data can be limited by the cost of communication and by privacy concerns. To determine the social welfare of an AMI, the economic gains should be estimated. For the planning of the low voltage (LV) network, a method for determining the value of an AMI still needs to be developed. Therefore, a planning methodology which allows various levels of measurement data availability has been developed. By applying this approach the value of different levels of AMI from an LV-network planning perspective can be determined. To illustrated the application of this approach a case study for the LV-network of a Dutch DNO is performed. The results show that an increase in measurement data can lead to €49-254 lower LV-network reinforcement costs. A detailed analysis of the results shows that already 50% of the possible cost reduction can be achieved if only 65% of the households have AMI data available.</p

    Optimisation of ITER Nb3Sn CICCs for coupling loss, transverse electromagnetic load and axial thermal contraction

    Get PDF
    The ITER cable-in-conduit conductors (CICCs) are built up from sub-cable bundles, wound in different stages, which are twisted to counter coupling loss caused by time-changing external magnet fields. The selection of the twist pitch lengths has major implications for the performance of the cable in the case of strain sensitive superconductors, i.e. Nb3Sn, as the electromagnetic and thermal contraction loads are large but also for the heat load from the AC coupling loss. Reduction of the transverse load and warm-up cool-down degradation can be reached by applying longer twist pitches in a particular sequence for the sub-stages, offering a large cable transverse stiffness, adequate axial flexibility and maximum allowed lateral strand support. Analysis of short sample (TF conductor) data reveals that increasing the twist pitch can lead to a gain of the effective axial compressive strain of more than 0.3 % with practically no degradation from bending. For reduction of the coupling loss, specific choices of the cabling twist sequence are needed with the aim to minimize the area of linked strands and bundles that are coupled and form loops with the applied changing magnetic field, instead of simply avoiding longer pitches. In addition we recommend increasing the wrap coverage of the CS conductor from 50 % to at least 70 %. The models predict significant improvement against strain sensitivity and substantial decrease of the AC coupling loss in Nb3Sn CICCs, but also for NbTi CICCs minimization of the coupling loss can be achieved. Although the success of long pitches to transverse load degradation was already demonstrated, the prediction of the combination with low coupling loss needs to be validated by a short sample test.Comment: to be published in Supercond Sci Techno

    Process competences to incorporate in higher education curricula

    Get PDF
    This study reports on a survey on project managers' priorities. The survey used ISO 21500 as a scaffold to ask various respondents, like junior, experienced, and senior project managers, project sponsors, and students, to share their perceptions on the priorities for junior project managers. The respondent groups shared similar perceptions. Furthermore, project type and sector had little effect on junior project managers' priorities. Experienced and senior project managers shared their own priorities as well. The perceptions of priorities for junior, experienced, and senior project managers were mostly alike. However, experienced and senior project managers' priorities seemed slightly more affected by project type and sector. A session with experts in project management and teaching project management highlighted that the results for junior project managers could provide accents for introducing project management to students in higher education, provided the entire playing field of project management is also introduced.</p

    The influence of knee rigidity on balance corrections: a comparison with responses of cerebellar ataxia patients

    Get PDF
    Knee rigidity due to aging or disease is associated with falls. A causal relationship between instability and knee rigidity has not been established. Here, we examined whether insufficient knee movement due to knee rigidity could underlie poor balance control in patients. We addressed this by examining the effect of artificially "locking” the knees on balance control in 18 healthy subjects, tested with and without individually fitted knee casts on both legs. Subjects were exposed to sudden rotations of a support surface in six different directions. The primary outcome measure was body centre of mass (COM) movement, and secondary outcome measures included biomechanical responses of the legs, pelvis and trunk. Knee casts caused increased backward COM movement for backward perturbations and decreased vertical COM movement for forward perturbations, and caused little change in lateral COM movement. At the ankles, dorsiflexion was reduced for backward perturbations. With knee casts, there was less uphill hip flexion and more downhill hip flexion. A major difference with knee casts was a reversed pelvis pitch movement and an increased forward trunk motion. These alterations in pitch movement strategies and COM displacements were similar to those we have observed previously in patients with knee rigidity, specifically those with spinocerebellar ataxia (SCA). Pelvis roll and uphill arm abduction were also increased with the casts. This roll movement strategy and minor changes in lateral COM movement were not similar to observations in patients. We conclude that artificial knee rigidity increases instability, as reflected by greater posterior COM displacement following support surface tilts. Healthy controls with knee casts used a pitch movement strategy similar to that of SCA patients to offset their lack of knee movement in regaining balance following multidirectional perturbations. This similarity suggests that reduced knee movements due to knee rigidity may contribute to sagittal plane postural instability in SCA patients and possibly in other patient groups. However in the roll plane, healthy controls rapidly compensate by adjusting arm movements and hip flexion to offset the effects of knee rigidit
    • …
    corecore